General Lighting Request

172 W Canton St, Roxbury, Ma, 02118

ID
#101003703694
Status
CLOSED
Opened
Closed
Description
Private Alley in the rear of 172 W Canton St. Verizon installed new wooden posts. #1. Need to transfer and raise the aluminum overhead feed, from the concrete Acorn post to post #VZ 70/4, leaving a pigtail. Drill out the wooden post and install an eye bolt. Wire up one standard bracket arm and install unit with one #70 LED standard luminare with photo cell. Splice and insulate all connections and test unit when completed. Verizon will transfer thier cables after completion. Thank you.
Location
172 W Canton St, Roxbury, Ma, 02118
42.34348907, -71.07586708
Photos

Activity

  • Submitted

  • Opened

  • Closed

    Case Resolved | Private Alley - Rear of 172 W Canton. Cut away old overhead cables, including triplex cable. Pulled approximately 175' of new aluminum cable for overhead feed. Installed four new standard bracket arms on newly installed Verizon posts. Wired up all arms and installed four new #70 LED standard fixtures with new photo cells. Removed #220 fixture and replaced it with new #70. Spliced and insulated all connection as needed and tested out all units. Area looks fantastic. Had engineer check lighting levels last night. HT, CG, EP.